Experiment 5: 1 sofa; 8' x 12' padding; 8' x 12' carpet

Circuit # Circuit Type Cord/Cable Type Trip Type Time to Trip
1 Conventional 18-2, SPT-1 Magnetic 237.4 s
2 AFCI 18-2, SPT-1 Magnetic 242.0 s
3 GFCI 18-2, SPT-1 Magnetic 237.9 s
4 Conventional 16-3 SJTW Magnetic 261.5 s
5 AFCI 16-3 SJTW Magnetic 255.6 s
6 GFCI 16-3 SJTW Magnetic 266.8 s
7 Conventional 12-2 NM Magnetic 254.6 s
8 AFCI 12-2 NM Magnetic 253.0 s
9 GFCI 12-2 NM Ground Fault 245.7 s
10 Conventional 12-3 NM Magnetic 260.2 s
11 AFCI 12-3 NM Ground Fault 248.1 s
12 GFCI 12-3 NM Ground Fault 240.9 s
13 Conventional 18-3 SVT Magnetic 239.5 s
14 AFCI 18-3 SVT Magnetic 240.7 s
15 GFCI 18-3 SVT Magnetic 241.0 s
16 Conventional NISPT-2 Magnetic 244.5 s
17 AFCI NISPT-2 Magnetic 243.6 s
18 GFCI NISPT-2 Magnetic 243.1 s

Experiment Video